Sensor Information
Sensors
The sensors that were monitored during the modal test consisted of
- 74 Accelerometers
- 30 PCB 336C31 (1 V/G, resolution 1 mG)
- 6 PCB 356A18 Triax (@3 channels, 1 V/G, res. 60 microG)
- 3 PCB XT352M85 (1 V/G, res. 70 microG)
- 4 PCB 393M25 (1 V/G, res. 1 microG)
- 2 PCB 333A50 (1 V/G, res. 80 microG)
- 9 PCB U393C/393C/393B (1 V/G, res. 100 microG)
- 5 PCB 308B02 (1 V/G, res. 500 microG)
- 3 PCB 393B31 (10 V/G, res. 1 microG)
- 1 Force input (Roving Impact Hammer)
- Accelerometer layout image
- Exact sensitivities are given in the MACL report (PDF format)
The sensors that were monitored during the operating (wind
excitation) tests were
- 62 Accelerometers
- 3 PCB356A18 triaxes and 3 PCB336C31 (1 triax) removed
(as shown in the figure)
- 24 Pressure Transducers on the Primary
- 15 Channels of wind data (5 sensors, each X, Y, Z).
- Locations
- Edge of primary (+X, -X, -Y)
'X' is the elevation axis
'+X' is to the right looking at M1
'-Y' is 'down' when the telescope looks to
horizon
- M2
- Top of dome
- Data Sheet (PDF format)
|