The CCD Mosaic Imager and its corrector, mounted on the 0.9-m telescope for the June engineering run.
The 4-m ADC is expected to yield similar performance over its 4 surfaces (that is, an additional 3-4% loss). Fabrication of these elements and their coatings should be completed by the time you read this.
4-m PF 0.9-m f/7.5
Mosaic T2KB Mosaic T2KA
Pixel scale,"/pix 0.26 0.47 0.43 0.68
Field,arcmin/side 36 16 59 23
The filter track holds 14 filters, each 5.8 inches square. By next spring we expect to have standard B, V, R, and I broad-band filters and two narrow-band filters, probably H-alpha and redshifted H-alpha, each with a 70 Å bandpass. We have not yet finalized parameters for the two narrow-band filters. Filters will all be 12 mm thick to preserve the focus. TV guide fields are located north and south of the science field and are viewed through separate broad-band filters.
Each CCD is read out through a single amplifier, and all the data streams are multiplexed back to the control computer where they are assembled into a single image. The entire mosaic can be read out in approximately 100 seconds. On-chip binning of pixels is supported, and this will speed up readout accordingly.
Although the CCDs have not been fully characterized yet, we expect that the typical read noise will be about 8 electrons. However, several of the CCDs show peculiar charge injection problems which raise the effective noise over parts of the chip to levels as high as 30 electrons. In addition, small areas (<15%) of two of the chips are compromised by significant traps. There are several bright or dark columns on each CCD; we expect that normal data processing will eliminate the effects of these. Because of a processing error in the CCD fabrication which results in poor charge transfer efficiency when the chips are very cold, they are operated at the unusually high temperature of -60C. This results in a dark signal of around 100-150 electrons/pixel/hour.
The chips are thick and front-illuminated. They are not coated with any kind of fluorescent coating, and so the quantum efficiency should be typical of front-illuminated devices, peaking at 50% at about 7000 Å and falling to below 10% below 4500 Å and above 9000 Å. We have not yet measured system throughputs; users might expect the count rates at V, R, and I to be half of the rates measured with the thinned Tek chips typically used at these two telescopes, and significantly worse than that in the blue. Consequently, the current system is not recommended for use below 4500 Å. Although these CCDs will be in use during the spring semester, NOAO is working to replace these devices with thinned science-grade CCDs.
At both 4-m and 0.9-m, new correctors have been designed and constructed to support the field of view and image quality requirements of the Mosaic imager, as mentioned above. The new 4-m corrector includes an atmospheric dispersion compensator, and it will be used with all CCD imaging at that focus. The 0.9-m corrector will be used with only the Mosaic, as it is incompatible with the gold guider. Image quality is expected to be excellent with both systems.
We therefore have come up with the following plan for users interested in taking advantage of the capabilities of the Mosaic during the spring semester. We divide potential Mosaic users into two classes: those whose science can be done with the current CCDs at the 4-m and 0.9-m, but who would achieve further benefit from use of the Mosaic; and those who would not be able to achieve their science goals without the Mosaic. All proposers should consider both the areal and sampling advantages provided by Mosaic, in contrast to the lower quantum efficiency (particularly in the blue), poorer cosmetics and higher readout noise and dark count of the Mosaic CCDs compared to the T2KA and T2KB CCDs. Users can refer to the expected Mosaic performance given above; any of the undersigned are available for phone or e-mail consultation. With the current Mosaic CCDs, it is likely that only projects requiring very significant areal coverage and not using blue filters will benefit from having Mosaic instead of T2KA/B.
For the first group of proposers, those able to do their science with T2KA at the 0.9-m or T2KB at the 4-m but desiring an "upgrade" to Mosaic, the standard proposal form should be filled out. For instrument, specify T2KA or T2KB followed by "(Mosaic if available)". It would be beneficial to include some discussion in the technical justification section of the proposal on how the Mosaic would help achieve the project's goals. We will block together the runs that would benefit from Mosaic. The schedule will reflect T2KA or T2KB for these runs. Once it becomes clear that Mosaic is sufficiently robust, though, we will contact the users and convert those blocks to Mosaic blocks.
For the second group of proposers, those wanting time only if Mosaic is available, we will use a methodology similar to that being employed for the Phoenix spectrograph. To save the effort of writing a full proposal before it is known whether Mosaic will be available, we request simply an expression of interest by the proposal deadline. This will be done by e-mail to kpno@noao.edu. The subject line should read "Mosaic expression of interest." The message should include the name(s) and e-mail address(es) of the investigators, a brief program title, which telescope (4-m and/or 0.9-m), the desired number of nights, and the desired lunar phase. Based on these expressions of interest, we will set aside a number of nights on the 4-m and 0.9-m late in the semester. Later, we will request more detailed proposals from those who have expressed interest. The timing of the proposal request will be determined by progress on Mosaic commissioning coupled with a desire to give proposers adequate notice. The proposals will then be reviewed and the nights assigned.
We trust that users will agree that the capabilities of Mosaic are sufficiently interesting to justify this extra effort in the proposal process, in order to make the instrument available for science observing as soon as possible.